ALM-17011 Abnormal Connection Between Oozie and YARN
Alarm Description
Oozie depends on YARN. After a task is submitted, the system checks YARN connectivity. This alarm is generated when the service fails the check for 5 consecutive times.
This alarm is cleared when the connection between Oozie and YARN becomes normal.
This section applies only to MRS 3.3.0-LTS or later.
Alarm Attributes
| Alarm ID | Alarm Severity | Auto Cleared |
|---|---|---|
| 17011 | Minor | Yes |
Alarm Parameters
| Parameter | Description |
|---|---|
| Source | Specifies the cluster for which the alarm was generated. |
| ServiceName | Specifies the service for which the alarm was generated. |
| RoleName | Specifies the role for which the alarm was generated. |
| HostName | Specifies the host for which the alarm was generated. |
| Trigger Condition | Specifies the threshold for triggering the alarm. |
Impact on the System
Running scheduling tasks are blocked and new scheduling tasks cannot be submitted.
Possible Causes
- The YARN service is abnormal.
- The connection between Oozie and YARN is abnormal.
Handling Procedure
Check the YARN service status.
- In the service list on FusionInsight Manager, check whether Running Status of YARN is Normal.
- Check whether there is an ALM-18000 Yarn Service Unavailable alarm in the alarm list.
- Rectify the fault by performing the operations provided for ALM-18000 YARN Service Unavailable.
- Wait for several minutes and check whether the alarm Abnormal Connection Between Oozie and Yarn is cleared.
- If yes, no further action is required.
- If no, go to Step 5.
Check the connectivity between Oozie and YARN.
- Log in to FusionInsight Manager, choose O&M > Log > Online Search, select the Oozie service, and search for the keyword [Oozie Alarm Enhancement][Yarn] in the log. View the cause in the log, and rectify the fault. In the alarm list, check whether the alarm Abnormal Connection Between Oozie and YARN is cleared.
- If yes, no further action is required.
- If no, go to Step 6.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Select Oozie for Service and click OK.
- Click
in the upper right corner, set Start Date and End Date for log collection to 10 minutes before and after the alarm generation time, respectively, and click Download. - Send the collected fault logs to O&M personnel for help.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.