Help Center/ MapReduce Service/ User Guide/ Alarm Reference (Applicable to MRS 3.x)/ ALM-12064 Host Random Port Range Conflicts with Cluster Used Port
Updated on 2022-09-26 GMT+08:00

ALM-12064 Host Random Port Range Conflicts with Cluster Used Port

Alarm Description

The system checks whether the random port range of the host conflicts with the range of ports used by the Cluster system every hour. The alarm is generated if they conflict. The alarm is automatically cleared when the random port range of the host is changed to the normal range.

Attribute

Alarm ID

Alarm Severity

Auto Clear

12064

Major

Yes

Parameters

Parameter

Description

Source

Specifiestheclusterorsystemforwhichthealarmisgenerated.

ServiceName

Specifies the name of the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Impact on the System

The default port of the Cluster system is occupied. As a result, some processes fail to be started.

Possible Causes

The random port range configuration is modified.

Procedure

Check the random port range of the system.

  1. In the alarm list on FusionInsight Manager, locate the row that contains the alarm, and view the IP address of the host for which the alarm is generated.
  2. Log in to the host where the alarm is generated as user root.
  3. Run the cat /proc/sys/net/ipv4/ip_local_port_range command to obtain the random port range of the host and check whether the minimum value is smaller than 32768.

    • If it is, go to 4.
    • If it is not, goto 7.

  4. Run the vim /etc/sysctl.conf command to change the value of net.ipv4.ip_local_port_range to 32768 61000. If this parameter does not exist, add the following configuration: net.ipv4.ip_local_port_range = 32768 61000.
  5. Run the sysctl -p /etc/sysctl.conf command for the modification to take effect.
  6. One hour later, check whether the alarm is cleared.

    • If it is, no further action is required.
    • If it is not, go to 7.

Collect fault information.

  1. On FusionInsight Manager, choose O&M > Log > Download.
  2. Select NodeAgent for Service and click OK.
  3. Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact the O&M personnel and send the collected log information.

Alarm Clearing

After the fault is rectified, the system automatically clears this alarm.

Related Information