- What's New
- Function Overview
- Service Overview (2.0)
- Getting Started (2.0)
-
User Guide (2.0)
- Introduction
- Access Center
- Dashboard
- Alarm Management
- Metric Browsing
- Log Analysis
-
Prometheus Monitoring
- Prometheus Monitoring
- Creating Prometheus Instances
- Managing Prometheus Instances
- Configuring a Recording Rule
- Metric Management
- Dashboard Monitoring
-
Access Guide
- Connecting Node Exporter
-
Exporter Access in the VM Scenario
- Access Overview
- MySQL Component Access
- Redis Component Access
- Kafka Component Access
- Nginx Component Access
- MongoDB Component Access
- Consul Component Access
- HAProxy Component Access
- PostgreSQL Component Access
- Elasticsearch Component Access
- RabbitMQ Component Access
- Access of Other Components
- Custom Plug-in Access
- Other Operations
- Obtaining the Service Address of a Prometheus Instance
- Viewing Prometheus Instance Data Through Grafana
- Reading Prometheus Instance Data Through Remote Read
- Reporting Self-Built Prometheus Instance Data to AOM
- Resource Usage Statistics
- Business Monitoring (Beta)
- Infrastructure Monitoring
- Settings
- Remarks
- Permissions Management
- Auditing
- Subscribing to AOM 2.0
- Upgrading to AOM 2.0
- Best Practices (2.0)
-
FAQs (2.0)
- Overview
- Dashboard
- Alarm Management
- Log Analysis
- Prometheus Monitoring
- Infrastructure Monitoring
-
Collection Management
- Are ICAgent and UniAgent the Same?
- What Can I Do If an ICAgent Is Offline?
- Why Is an Installed ICAgent Displayed as "Abnormal" on the Agent Management Page?
- Why Can't I View the ICAgent Status After It Is Installed?
- Why Can't AOM Monitor CPU and Memory Usage After ICAgent Is Installed?
- How Do I Obtain an AK/SK?
- FAQs About ICAgent Installation
- How Do I Enable the Nginx stub_status Module?
- Other FAQs
-
API Reference
- Before You Start
- API Overview
- Calling APIs
-
APIs
-
Alarm
- Querying the Event Alarm Rule List
- Adding an Event Alarm Rule
- Modifying an Event Alarm Rule
- Deleting an Event Alarm Rule
- Obtaining the Alarm Sending Result
- Deleting a Silence Rule
- Adding a Silence Rule
- Modifying a Silence Rule
- Obtaining the Silence Rule List
- Querying an Alarm Action Rule Based on Rule Name
- Adding an Alarm Action Rule
- Deleting an Alarm Action Rule
- Modifying an Alarm Action Rule
- Querying the Alarm Action Rule List
- Querying Metric or Event Alarm Rules
- Adding or Modifying Metric or Event Alarm Rules
- Deleting Metric or Event Alarm Rules
- Querying Events and Alarms
- Counting Events and Alarms
- Reporting Events and Alarms
-
Monitoring
- Querying Time Series Objects
- Querying Time Series Data
- Querying Metrics
- Querying Monitoring Data
- Adding Monitoring Data
- Adding or Modifying One or More Service Discovery Rules
- Deleting a Service Discovery Rule
- Querying Existing Service Discovery Rules
- Adding a Threshold Rule
- Querying the Threshold Rule List
- Modifying a Threshold Rule
- Deleting a Threshold Rule
- Querying a Threshold Rule
- Deleting Threshold Rules in Batches
-
Prometheus Monitoring
- Querying Expression Calculation Results in a Specified Period Using the GET Method
- (Recommended) Querying Expression Calculation Results in a Specified Period Using the POST Method
- Querying the Expression Calculation Result at a Specified Time Point Using the GET Method
- (Recommended) Querying Expression Calculation Results at a Specified Time Point Using the POST Method
- Querying Tag Values
- Obtaining the Tag Name List Using the GET Method
- (Recommended) Obtaining the Tag Name List Using the POST Method
- Querying Metadata
- Log
- Prometheus Instance
- Configuration Management
-
Alarm
- Historical APIs
- Examples
- Permissions Policies and Supported Actions
- Appendix
- SDK Reference
-
Service Overview (1.0)
- What Is AOM?
- Product Architecture
- Functions
- Application Scenarios
- Edition Differences
-
Metric Overview
- Introduction
- Network Metrics and Dimensions
- Disk Metrics and Dimensions
- Disk Partition Metrics
- File System Metrics and Dimensions
- Host Metrics and Dimensions
- Cluster Metrics and Dimensions
- Container Metrics and Dimensions
- VM Metrics and Dimensions
- Instance Metrics and Dimensions
- Service Metrics and Dimensions
- Restrictions
- Privacy and Sensitive Information Protection Statement
- Relationships Between AOM and Other Services
- Basic Concepts
- Permissions
- Billing
- Getting Started (1.0)
-
User Guide (1.0)
- Overview
- Subscribing to AOM
- Permissions Management
- Connecting Resources to AOM
- Monitoring Overview
- Alarm Management
- Resource Monitoring
- Log Management
- Configuration Management
- Auditing
- Upgrading to AOM 2.0
- Best Practices (1.0)
-
FAQs (1.0)
- User FAQs
-
Consultation FAQs
- What Are the Usage Restrictions of AOM?
- What Are the Differences Between AOM and APM?
- How Do I Distinguish Alarms from Events?
- What Is the Relationship Between the Time Range and Statistical Cycle?
- Does AOM Display Logs in Real Time?
- How Can I Do If I Cannot Receive Any Email Notification After Configuring a Threshold Rule?
- Why Are Connection Channels Required?
-
Usage FAQs
- What Can I Do If I Do Not Have the Permission to Access SMN?
- What Can I Do If Resources Are Not Running Properly?
- How Do I Set the Full-Screen Online Duration?
- What Can I Do If the Log Usage Reaches 90% or Is Full?
- How Do I Obtain an AK/SK?
- How Can I Check Whether a Service Is Available?
- Why Is the Status of an Alarm Rule Displayed as "Insufficient"?
- Why the Status of a Workload that Runs Normally Is Displayed as "Abnormal" on the AOM Page?
- How Do I Create the apm_admin_trust Agency?
- What Is the Billing Policy of Logs?
- Why Can't I See Any Logs on the Console?
- What Can I Do If an ICAgent Is Offline?
- Why Can't the Host Be Monitored After ICAgent Is Installed?
- Why Is "no crontab for root" Displayed During ICAgent Installation?
- Why Can't I Select an OBS Bucket When Configuring Log Dumping on AOM?
- Why Can't Grafana Display Content?
Alarm Tags and Annotations
When creating alarm rules, you can set alarm tags and annotations. Tags are attributes that can be used to identify alarms. They are applied to alarm noise reduction scenarios. Annotations are attributes that cannot be used to identify alarms. They are applied to scenarios such as alarm notification and message templates.
Alarm Tag Description
- Alarm tags can apply to grouping rules, suppression rules, and silence rules. The alarm management system manages alarms and notifications based on the tags.
- Each tag is in "key:value" format and can be customized. Each key and value can contain only letters, digits, and underscores (_).
- If you set a tag when creating an alarm rule, the tag is automatically added as an alarm attribute when an alarm is triggered.
- In a message template, the $event.metadata.key1 variable specifies a tag. For details, see Table 2.
If tag policies related to AOM have already been set, add alarm tags based on these policies. If a tag does not comply with the policies, tag addition may fail. Contact your organization administrator to learn more about tag policies.
Alarm Annotation Description
- Annotations are attributes that cannot be used to identify alarms. They are applied to scenarios such as alarm notification and message templates.
- Each annotation is in "key:value" format and can be customized. You can create up to 10 custom annotations. The key and value can only contain letters, digits, and underscores (_).
- In a message template, the $event.annotations.key2 variable specifies an annotation. For details, see Table 2.
Managing Alarm Tags and Annotations
You can add, delete, modify, and query alarm tags or annotations on the alarm rule page.
- Log in to the AOM 2.0 console.
- In the navigation pane, choose Alarm Management > Alarm Rules.
- Click Create, or locate a desired alarm rule and click
in the Operation column.
- On the displayed page, click Advanced Settings.
- Under Alarm Tag or Alarm Annotation, click
and enter a key and value.
- Click OK to add an alarm tag or annotation.
NOTE:
- Adding multiple alarm tags or annotations: Click
multiple times to add alarm tags or annotations (max.: 10).
- Modifying an alarm tag or annotation: Move the cursor to a desired alarm tag or annotation and click
to modify them.
- Deleting an alarm tag or annotation: Move the cursor to a desired alarm tag or annotation and click
to delete them.
- Adding multiple alarm tags or annotations: Click
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.