ALM-17008 Abnormal Connection Between Oozie and ZooKeeper
Alarm Description
In HA mode, Oozie depends on ZooKeeper. This alarm is generated when the connection between Oozie and ZooKeeper is abnormal for three consecutive times.
This alarm is cleared when the connection between Oozie and ZooKeeper becomes normal.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
17008 |
Minor |
Yes |
Alarm Parameters
Parameter |
Description |
---|---|
Source |
Specifies the cluster for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
Trigger Condition |
Specifies the threshold for triggering the alarm. |
Impact on the System
In HA mode, the Oozie service will restart if this alarm is reported.
Possible Causes
- The ZooKeeper service is abnormal.
- Oozie fails to connect to ZooKeeper.
Handling Procedure
Check the ZooKeeper service status.
- In the service list on FusionInsight Manager, check whether Running Status of ZooKeeper is Normal.
- In the alarm list, check whether ALM-13000 ZooKeeper Service Unavailable is reported.
- Rectify the fault by performing the operations provided for ALM-13000 ZooKeeper Service Unavailable.
- Wait for several minutes and check whether the alarm Abnormal Connection Between Oozie and ZooKeeper is cleared.
- If yes, no further action is required.
- If no, go to 5.
Check the connectivity between Oozie and ZooKeeper.
- Log in to FusionInsight Manager, choose O&M > Log > Online Search, select the Oozie service, and search for the keyword [Oozie Alarm Enhancement][ZooKeeper] in the log. View the cause in the log, and rectify the fault. In the alarm list, check whether the alarm Abnormal Connection Between Oozie and ZooKeeper is cleared.
- If yes, no further action is required.
- If no, go to 6.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Select Oozie for Service and click OK.
- Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.