ALM-12084 Password of User ommdba Expired
Description
The system starts at 00:00 every day to check whether the password of user ommdba has expired every 8 hours. This alarm is generated if the password has expired.
This alarm is cleared when the expiration time of user ommdba password is reset and the user password status becomes normal.
Attribute
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
12084 |
Major |
Yes |
Parameters
Name |
Meaning |
---|---|
Source |
Specifies the cluster or system for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
Impact on the System
The password of user ommdba has expired. The node trust relationship is unavailable, and FusionInsight Manager cannot manage the services.
Possible Causes
The password of user ommdba for the host has expired.
Procedure
Check whether the password of user ommdba in the system has expired.
- Log in to the faulty node as user root.
Run the chage -l ommdba command to view the information about the password of user ommdba.
- View the value of Password expires to check whether the user configurations have expired.
If the parameter value is never, the user and password are valid permanently; if the value is a date, check whether the user and password have expired.
- Run the chage -M 'days' ommdba command to set the validity period of the password for user ommdba. Eight hours later, check whether the alarm is automatically cleared.
- If it is, no further action is required.
- If it is not, go to 4.
Collect fault information.
- On FusionInsight Manager, choose O&M > Log > Download.
- Select NodeAgent for Service and click OK.
- Click in the upper right corner. In the displayed dialog box, set Start Date and End Date to 10 minutes before and after the alarm generation time respectively and click OK. Then, click Download.
- Contact the O&M personnel and send the collected log information.
Alarm Clearing
This alarm will be automatically cleared after the fault is rectified.
Related Information
None
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.