Symptom

For Red Hat 7 or CentOS 7, cloud-init-local may fail to start up. As a result, BMS failed to inject data correctly. When you run the systemctl status cloud-init-local.service command, the message "OSError: [Errno 2] No such file or directory" is displayed.

Solution

For Red Hat 7 and CentOS 7, if the libselinux version is earlier than 2.5.7, cloud-init-local may fail to start up. This is a known issue and has been fixed in libselinux 2.5.7. For details, see https://bugzilla.redhat.com/show_bug.cgi?id=1406520. If you are creating a Red Hat 7 or CentOS 7 image, upgrade libselinux to 2.5.7 or later after you configure the yum source in section "Installing Cloud-Init > SUSE/Red Hat/CentOS/Oracle Linux/Ubuntu/Debian > CentOS".