ALM-50401 Number of JobServer Jobs Waiting to Be Executed Exceeds the Threshold
Alarm Description
The system checks the number of jobs submitted to JobServer every 30 seconds. This alarm is generated when the number of jobs to be executed exceeds 800.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
50401 |
Critical (default threshold: 900) Major (default threshold: 800) |
Yes |
Alarm Parameters
Parameter |
Description |
---|---|
Source |
Specifies the cluster or system for which the alarm was generated. |
ServiceName |
Specifies the service for which the alarm was generated. |
RoleName |
Specifies the role for which the alarm was generated. |
HostName |
Specifies the host for which the alarm was generated. |
Impact on the System
Too many JobServer jobs are detected in the queue. For details about the queue usage, see the Additional Information field of this alarm. The impacts are as follows:
- When the number of JobServer jobs in the queue reaches the maximum (1000 by default), new jobs cannot be added.
- Before the number of JobServer jobs in the queue reaches the maximum, new JobServer jobs cannot be submitted quickly. For example, it takes more time (even hours) to submit added jobs or add new jobs to Yarn.
Possible Causes
Too many jobs are submitted instantaneously.
Handling Procedure
- Log in to FusionInsight Manager and choose Cluster > Services > JobGateway.
- Click the Instances tab, click Add Instance, and add JobServer instances based on the number of submitted jobs.
- After the instances are added, restart the JobGateway service.
- Wait 5 minutes and check whether the alarm is automatically cleared.
If yes, no further action is required.
If no, go to 5.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select JobGateway for the target cluster.
- Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.
Feedback
Was this page helpful?
Provide feedbackThank you very much for your feedback. We will continue working to improve the documentation.