Help Center/ MapReduce Service/ User Guide/ Alarm Reference (Applicable to MRS 3.x)/ ALM-45292 PolicySync GC Duration Exceeds the Threshold
Updated on 2024-04-11 GMT+08:00

ALM-45292 PolicySync GC Duration Exceeds the Threshold

Alarm Description

The system checks the GC duration of the PolicySync process every 60 seconds. This alarm is generated when the GC duration of the PolicySync process exceeds the threshold for five consecutive times. This alarm is cleared when the GC duration is less than the threshold.

Alarm Attributes

Alarm ID

Alarm Severity

Auto Cleared

45292

Critical (default threshold: 20000ms)

Major (default threshold: 12000ms)

Yes

Alarm Parameters

Parameter

Description

Source

Specifies the cluster for which the alarm is generated.

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Trigger Condition

Specifies the threshold for triggering the alarm.

Impact on the System

PolicySync responds slowly.

Possible Causes

The heap memory of the PolicySync process is overused or inappropriately allocated, causing frequent occurrence of the GC process.

Handling Procedure

Check the GC duration.

  1. Log in to FusionInsight Manager and choose O&M > Alarm > Alarms > ALM-45292 PolicySync GC Duration Exceeds the Threshold. Check the location information of the alarm and view the host name of the instance for which the alarm is generated.
  2. On FusionInsight Manager, choose Cluster > Services > Ranger > Instance. Select the role corresponding to the host name of the instance for which the alarm is generated and click the drop-down list in the upper right corner of the chart area. Choose Customize > GC > PolicySync GC Duration. Click OK.

    Figure 1 PolicySync GC Duration

  3. Check whether the GC duration of the PolicySync process collected every minute exceeds the threshold (12 seconds by default).

    • If yes, go to 4.
    • If no, go to 6.

  4. On FusionInsight Manager, choose Cluster > Services > Ranger > Instance > PolicySync. Click Instance Configuration and then All Configurations, and choose PolicySync > System. Set -Xmx in the GC_OPTS parameter to a larger value based on site requirements and save the configuration.

    If this alarm is generated, the heap memory configured for PolicySync cannot meet the heap memory required by the PolicySync process. You are advised to change the value of -Xmx in GC_OPTS to twice that of the heap memory used by PolicySync. You can change the value based on the actual service scenario. Refer to 2 to view the PolicySync heap memory usage.

  5. Restart the affected services or instances and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, and select Ranger for the target cluster.
  3. Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact O&M personnel and provide the collected logs.

Alarm Clearance

This alarm is automatically cleared after the fault is rectified.

Related Information

None.