Help Center/ MapReduce Service/ User Guide/ Alarm Reference (Applicable to MRS 3.x)/ ALM-29006 Number of ODBC Connections to Impalad Exceeds the Threshold
Updated on 2024-05-07 GMT+08:00

ALM-29006 Number of ODBC Connections to Impalad Exceeds the Threshold

Alarm Description

The system checks the number of client connections to the Impalad node every 30 seconds. This alarm is generated when the number of client connections exceeds the customized threshold (60 by default).

This alarm is automatically cleared when the number of client connections is less than the threshold.

Alarm Attributes

Alarm ID

Alarm Severity

Auto Cleared

29006

Major

Yes

Alarm Parameters

Type

Parameter

Description

Location Information

Source

Specifies the cluster for which the alarm was generated.

ServiceName

Specifies the service for which the alarm was generated.

RoleName

Specifies the role for which the alarm was generated.

HostName

Specifies the host for which the alarm was generated.

Additional Information

Trigger Condition

Specifies the threshold for triggering the alarm.

Impact on the System

New client connections may be blocked or even fail.

Possible Causes

The number of client connections maintained by the Impalad service is too large or the threshold is too small.

Handling Procedure

  1. On FusionInsight Manager, choose O&M > Alarm > Thresholds > Impala > Connections > Number of ODBC Connections to Impalad Process (Impalad) to check the threshold.

  2. Check the number of ODBC applications connected to Impalad and stop idle applications. Check whether the alarm is automatically cleared.

    • If yes, no further action is required.
    • If no, go to 3 to change the number of concurrent connections supported by Impalad.

  3. On FusionInsight Manager, choose Cluster > Impala > Configurations > All Configurations > Impalad > Customization. Add the customized parameter --fe_service_threads. The default value of this parameter is 64. Change the value as required and click Save.

  4. After the query tasks on all clients are complete, click the Instance tab. Select all Impalad instances, and restart them.

  5. After the restart is complete, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

Collect fault information.

  1. On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
  2. Expand the Service drop-down list, and select Impala for the target cluster.
  3. Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
  4. Contact O&M personnel and provide the collected logs.

Alarm Clearance

After the fault that triggers the alarm is rectified, the alarm is automatically cleared.

Related Information

None