Modifying Alarm Notification Information in an Alarm Rule
Function
This API is used to modify alarm notification information in an alarm rule.
URI
PUT /v2/{project_id}/alarms/{alarm_id}/notifications
|
Parameter |
Mandatory |
Type |
Description |
|---|---|---|---|
|
project_id |
Yes |
String |
Definition Project ID. It is used to specify the project that an asset belongs to. You can query the assets of a project by project ID. You can obtain the project ID from the API or console. For details, see Obtaining a Project ID. Constraints N/A Range 1 to 64 characters Default Value N/A |
|
alarm_id |
Yes |
String |
Definition Alarm rule ID. Constraints N/A Range The value starts with al and is followed by 22 characters of letters, digits, or a combination of both. Default Value N/A |
Request Parameters
|
Parameter |
Mandatory |
Type |
Description |
|---|---|---|---|
|
Content-Type |
No |
String |
Definition MIME type of the request body. Constraints: None Value range: The value can contain 1 to 64 characters. Default value: The default type is application/json; charset=UTF-8. |
|
X-Auth-Token |
No |
String |
Definition User token. Constraints: None Value range: The value can contain 1 to 16,384 characters. Default value: None |
|
Parameter |
Mandatory |
Type |
Description |
|---|---|---|---|
|
notification_enabled |
Yes |
Boolean |
Definition Whether to enable alarm notifications. Constraints If this parameter is set to true, other fields are mandatory. If it is set to false, other fields are optional. Range A boolean value, which can be:
Default Value N/A |
|
alarm_notifications |
No |
Array of Notification objects |
Definition: Notification group or topic subscription for alarm notifications. Constraints: You can configure 0 to 10 notification groups or topic subscriptions. |
|
ok_notifications |
No |
Array of Notification objects |
Definition: Information about the notification group or topic subscription when the alarm is cleared. Constraints: You can configure 0 to 10 notification groups or topic subscriptions. |
|
notification_begin_time |
No |
String |
Definition Time when alarm notifications were enabled. Constraints N/A Range The value allows 1 to 64 characters and can only contain digits and colons (:). Default Value N/A |
|
notification_end_time |
No |
String |
Definition Time when alarm notifications were disabled. Constraints N/A Range The value allows 1 to 64 characters and can only contain digits and colons (:). Default Value N/A |
|
effective_timezone |
No |
String |
Definition Time zone, for example, GMT-08:00, GMT+08:00, or GMT+0:00. Constraints N/A Range 1 to 16 characters Default Value N/A |
|
Parameter |
Mandatory |
Type |
Description |
|---|---|---|---|
|
type |
Yes |
String |
Definition Notification type. Constraints N/A Range The value can be:
Default Value N/A |
|
notification_list |
Yes |
Array of strings |
Definition Recipients to be notified of the alarm status changes. The value of topicUrn can be obtained from SMN. For details, see section "Querying Topics". Constraints If type is set to notification, the value of notification_list cannot be left blank. If type is set to autoscaling, the value of notification_list must be left blank. If notification_enabled is set to true, you must specify either alarm_notifications or ok_notifications. If both alarm_notifications and ok_notifications are specified, their notification_list values must be the same. A maximum of 20 recipients are allowed. |
Response Parameters
Status code: 200
|
Parameter |
Type |
Description |
|---|---|---|
|
notification_enabled |
Boolean |
Definition Whether to enable alarm notifications. Range A boolean value, which can be:
|
|
alarm_notifications |
Array of NotificationResp objects |
Definition: Notification group or topic subscription for alarm notifications. |
|
ok_notifications |
Array of NotificationResp objects |
Definition: Information about the notification group or topic subscription when the alarm is cleared. |
|
notification_begin_time |
String |
Definition Time when alarm notifications were enabled. Range The value allows 1 to 64 characters and can only contain digits and colons (:). |
|
notification_end_time |
String |
Definition Time when alarm notifications were disabled. Range The value allows 1 to 64 characters and can only contain digits and colons (:). |
|
Parameter |
Type |
Description |
|---|---|---|
|
type |
String |
Definition Notification type. Range The value can be:
|
|
notification_list |
Array of strings |
Definition Recipients to be notified of the alarm status changes. The value of topicUrn can be obtained from SMN. For details, see section "Querying Topics". |
Status code: 400
|
Parameter |
Type |
Description |
|---|---|---|
|
error_code |
String |
Status codes customized by each cloud service when a request error occurs. |
|
error_msg |
String |
Request error message. |
|
request_id |
String |
Request ID. |
Status code: 500
|
Parameter |
Type |
Description |
|---|---|---|
|
error_code |
String |
Status codes customized by each cloud service when a request error occurs. |
|
error_msg |
String |
Request error message. |
|
request_id |
String |
Request ID. |
Example Requests
Modifying alarm notification information in an alarm rule.
{
"notification_enabled" : true,
"alarm_notifications" : [ {
"type" : "notification",
"notification_list" : [ "urn:smn:cn-north-7:65c438cab60xxxxxxx:CES_notification_group_MGj4AJ03X" ]
} ],
"ok_notifications" : [ {
"type" : "notification",
"notification_list" : [ "urn:smn:cn-north-7:65c438cab60xxxxxxx:CES_notification_group_MGj4AJ03X" ]
} ],
"notification_begin_time" : "00:00",
"notification_end_time" : "23:59"
}
Example Responses
Status code: 200
Alarm notification information modified.
{
"notification_enabled" : true,
"alarm_notifications" : [ {
"type" : "",
"notification_list" : [ ]
} ],
"ok_notifications" : [ {
"type" : "",
"notification_list" : [ ]
} ],
"notification_begin_time" : "00:00",
"notification_end_time" : "23:59"
}
Status Codes
|
Status Code |
Description |
|---|---|
|
200 |
Alarm notification information modified. |
|
400 |
Parameter verification failed. |
|
500 |
Internal system error. |
Error Codes
See Error Codes.
Feedback
Was this page helpful?