Service Configuration

OneAccess can interconnect with applications through OAuth, SAML, OIDC, and CAS. It also provides OTP and RADIUS services. View the parameters of these services when you interconnect OneAccess with different applications.

OTP

An OTP is generated by a virtual MFA device in compliance with the Time-based One-time Password Algorithm (TOTP) standard. MFA devices can be hardware- or software-based. Currently, HUAWEI CLOUD supports software-based virtual MFA devices, which are application programs running on smart devices such as mobile phones.

OneAccess supports OTP configuration. You can also configure the OTP parameters to your virtual MFA device. For details, see the documentation of the virtual MFA device.

Table 1 Parameter configuration

Parameter

Description

Encryption Algorithm

Default algorithm: HMACSHA1. This parameter cannot be modified.

Code Digits

Default value: 6. This parameter cannot be modified.

Generation Period (s)

Default value: 30. This parameter cannot be modified.

Time Offset

Default value: 0. This parameter cannot be modified.

Base Time

Default value: GMT. This parameter cannot be modified.

MFA Authentication with Password

If you enable this option, users need to enter an OTP code in addition to their usernames and passwords during OTP login. By default, this option is disabled.

To use OTP login for an application, ensure that you have enabled OTP authentication for PC or mobile devices on the login configuration page of the application.

IdP

To establish a SAML-based trust relationship with an application, upload the metadata file of the IdP to the SP server. For details about how to upload the metadata, see the documentation of the SP.

Click IdP on the Server Settings page, and click Download IdP Metadata in the upper right. Then upload the downloaded metadata file to your SP server.

Table 2 IdP service parameters

Parameter

Description

IDP EntityId

Unique identifier of the IdP.

SSO URL

URL for SSO.

IdP Logout URL

URL for SLO.

IdP Certificate

A public key certificate used for signature verification. The signing certificate in the metadata file is used by applications during user access to ensure that assertions are credible and complete.

Assertion Request Time Window

Default value: 2 minutes.

Request Signature

By default, this option is enabled.

Assertion Signature

By default, this option is enabled.

Assertion Encryption

By default, this option is disabled.

OIDC

To establish an OIDC-based trust relationship with an application, obtain the required port information.

Click OIDC. On the OIDC page, click OIDC Discovery in the upper right corner to view the OIDC data.

Parameter

Description

Authentication URL

Interface for authenticating users during application access. The default value is used.

Token URL

Interface for obtaining user tokens. The default value is used.

User Information

Only the default value can be used.

Refresh Token URL

Interface for refreshing user tokens. The default value is used.

CAS

To establish a CAS-based trust relationship with an application, view and configure the CAS service information.

Click CAS, and view the CAS configuration parameters.

Parameter

Description

Server Prefix

Prefix of the CAS server URL.

Login URL

Login URL of the CAS server.

ST Validity Period

Validity period of a returned service ticket (ST). Set a validity period from 3 to 15 minutes.

RADIUS

To configure enterprise devices, view the RADIUS configuration information.

Parameter

Description

RADIUS Server

URL of the RADIUS Server.

Port

Authentication port of the RADIUS server for interconnecting with enterprise devices.

Supported Protocols

Protocols supported by the RADIUS server when interconnecting with enterprise devices. The protocols include: PAP, CHAP, MS-CHAPv1, and MS-CHAPv2.

API Authentication

To register open APIs with OneAccess, view the API authentication settings and configure them for interaction with your applications.

Parameter

Description

Signature Algorithm

Only the default value can be used.

Public Key

Public key for signature verification. Only the default value can be used.

Encryption Algorithm

Only the default value can be used.

Algorithm Key

Key used by the encryption algorithm. Click Modify to set a key.

Validity Period

Validity period of the ID token. The default value is 30 minutes.