(Optional) Installing the V5 Server Onboard NIC Driver
Scenarios
This section describes how to install the X722 NIC driver so that BMSs can be provisioned on V5 servers. Skip this section for other types of servers.
This section uses CentOS 7.3 as an example to describe how to install the V5 server onboard NIC driver.
Procedure
- Upload the NIC-X710_XL710_X722-CentOS7.3-i40e-2.4.6-1.x86_64.rpm package obtained in section Preparations to the VM. For details, see step 11 in section Configuring the VM Environment.
- Enter the directory where the .rpm package is stored and run the following command to install the driver:
rpm -ivh NIC-X710_XL710_X722-CentOS7.3-i40e-2.4.6-1.x86_64.rpm
[root@localhost i40e]# rpm -ivh NIC-X710_XL710_X722-CentOS7.3-i40e-2.4.6-1.x86_64.rpm Preparing... ################################## [100%] Updating / installing... 1:i40e-2.4.6-1 ################################## [100%] original pci.ids saved in /usr/local/share/i40e Updating initrd... Using dracut to update initrd... Successfully updated initrd. [root@localhost i40e]#
- After the installation is complete, run the rpm -qa | grep i40e command. The installation is successful if information similar to the following is displayed:
i40e-2.4.6-1.x86_64
Last Article: Preparations
Next Article: (Optional) Installing the mpt3 Driver
Did this article solve your problem?
Thank you for your score!Your feedback would help us improve the website.