OIDC Authentication

Introduction

OIDC is an interoperable authentication protocol based on the OAuth 2.0 family of specifications. For details, see Welcome to OpenID Connect.

This section describes how to integrate a third-party authentication provider with OneAccess through OIDC. OKta is used as an example.

The procedure for accessing the user portal on a PC is used for illustration. Select and configure an application that meets your service requirements.

Configuration Process

Figure 1 Configuration process

Prerequisites

  • You have administrator permissions for the Okta platform. For details, see the documentation of the Okta platform.
  • You have permissions to access the administrator portal.

Creating an Application on Okta

Create an application and configure authorization information for OneAccess on the Okta platform to establish a trust on OneAccess.

  1. Log in to the Okta platform.
  2. On the Okta platform, choose Applications > Add Application, click Create New App, and set the application parameters. For details, see the documentation of the Okta platform.

    When you configure the application, set Login redirect URIs to the invocation address automatically generated for the authentication provider that you have added in OneAccess. For details, see Table 1. For example: https://xxx.huaweioneaccess.com/api/v1/oidc/sso/2***71-8***-D***1.

    Figure 2 Configuring parameters
    Figure 3 Configuring login redirect URIs

  3. Configure the application parameters and authorize access to specific users. For details, see the documentation of the Okta platform.

    Figure 4 Configuring application parameters
    Figure 5 Authorizing users

Adding an OIDC Authentication Provider

Add an OIDC authentication provider and configure the application information in OneAccess.

  1. Log in to the administrator portal.
  2. In the top navigation pane, choose Authentication > Authentication Providers. Then click OIDC.

    Figure 6 Clicking OIDC

  3. On the OIDC Authentication Providers page, click Add Authentication Provider in the upper right corner and set the parameters required.

    Figure 7 Configuring parameters

    Table 1 Configuration parameters

    Parameter

    Mandatory

    Description

    Icon

    No

    Upload a PNG, JPG, or GIF image whose size does not exceed 50 KB. The recommended size is 32 x 32 pixels.

    Display Name

    Yes

    Display name of the authentication provider, for example, OpenID Connect.

    Authentication Type

    Yes

    User authentication type. Select Initiated by user.

    NOTE:
    • The authentication type cannot be changed once specified.
    • If authentication is initiated from the application side, select Initiated by authentication provider.

    Public Key Format

    Yes

    Select a public key format based on the application.

    Public Key

    Yes

    Obtain the public key displayed in jwks_uri of OIDC or from the authentication provider administrator. The public key must match the selected public key format.

    • If the public key format is JWKURL, the public key is https://{Okta domain name}/oauth2/v1/keys.
    • If the public key format is JSON, the public key is the value in https://{Okta domain name}/oauth2/v1/keys.

    Signature Algorithm

    Yes

    The default value is RS256.

    Audience

    Yes

    If Authentication Type is set to Initiated by authentication provider, set this parameter to the value of Audience generated for the application created in 1.

    Process Type

    Yes

    Select a process type based on the application configuration. For example, select Authorization code from the drop-down list.

    response Type

    Yes

    The default value is code.

    scope

    Yes

    Corresponds to the value of scopes of the OIDC authentication provider. The value of this parameter must contain openid. For example, openid email.

    authrozationUrl

    Yes

    Corresponds to the value of EMBED LINK of the OIDC authentication provider.

    clientld

    Yes

    Corresponds to the value of Client ID of the OIDC authentication provider.

    PKCE

    Yes

    By default, this option is disabled. If Authentication Type is set to Initiated by user, enable this option.

    tokenUrl

    Yes

    Token address, which you can obtain from token_endpoint of OIDC. The format is https://{Okta domain name}/api/v1/oauth2/token.

    logoutUrl

    No

    Global logout address of the application, which you can obtain from the application.

    Callback URL

    Yes

    Corresponds to the Login redirect URIs parameter of the application. The value of this parameter is automatically generated.

    Source Attribute

    Yes

    Unique user attribute on the OIDC authentication provider side. For example, email.

    Related User Attribute

    Yes

    OneAccess user attribute that maps the user attribute of the OIDC authentication provider. For example, email.

    No User Associated

    Yes

    Operation that will be performed if a user successfully logs in through OIDC authentication but fails to be associated with a system user.

    To map other attributes, such as full name, set No User Associated to Automatically create users, and add the desired mappings. For details, see Table 2.

    Table 2 Mapping parameters

    Parameter

    Description

    User Attribute

    Attribute (such as full name) in OneAccess that maps to the OIDC application.

    Mapping Type

    Mode of user attribute mapping between OneAccess and the OIDC application.

    Authentication Provider Attribute Name

    User attribute in the OIDC application, for example, name.

Enabling OIDC Authentication

  1. Log in to the administrator portal.
  2. In the top navigation pane, choose Resources > Applications. Then select UserCenter in the Pre-integrated Applications section.
  3. On the application information page, click the application icon.
  4. On the application details page, choose Login Settings > Web Applications, enable OIDC authentication, and select the authentication provider added in Adding an OIDC Authentication Provider.

    Figure 8 Enabling OIDC authentication

Logging In to the User Portal Through OIDC Authentication

  1. Go to the user portal login page, select OIDC, enter the username and password of the user authorized in 3, and click Log In.

    Figure 9 Selecting OIDC

  2. After login, go to the administrator portal, choose Users > Organizations and Users, and view the automatically created user.

    • To automatically create a new user if the authorized user is not associated with any system user, set No User Associated to Automatically create users. For details, see Table 1.
    • If the user attribute email is unique, users automatically created in the preceding scenario belong to the first root organization in OneAccess by default.
    Figure 10 Viewing users